.delivery-table { width: 100%; border-collapse: collapse; margin-top: 10px; table-layout: fixed; } .delivery-table th, .delivery-table td { border: 1px solid #333; padding: 10px; text-align: left; vertical-align: top; font-size: 14px; } .delivery-table th { background-color: #f5f5f5; font-weight: bold; } /* Smaller zone column */ .zone { width: 70px; font-weight: bold; text-align: left; } /* Give more room to states */ .states { width: auto; } /* Subtle separation between zones */ .delivery-table tr.zone-divider td { border-top: 2px solid #333; } Zone States 1 Arizona, California, Idaho, Nevada, Oregon, Utah, Washington, Montana, New Mexico, Wyoming, Colorado 2 Georgia, Alabama, Mississippi, Tennessee, Kentucky, Florida, South Carolina, North Carolina, Ohio, Indiana, Illinois, Michigan, Wisconsin, West Virginia, Virginia, Pennsylvania, Maryland, Delaware, New Jersey, Connecticut, Massachusetts, Rhode Island, Maine, New Hampshire, Vermont, New York 3 Louisiana, Texas, Oklahoma, Missouri, Minnesota, North Dakota, South Dakota, Nebraska, Kansas, Arkansas, Iowa Rmax Durasheath®-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded to inorganic polymer-coated glass fiber mat facers on each side. It offers energy performance and superior durability and is intended for use in exterior walls with stucco veneer, concrete sandwich panels, and many other building envelope applications, including those where an impermeable foil-faced product is not desired. Thickness Sq Ft/Pallet Sheets Per Pallet R-Value Minimum Order 0.5" 3072 96 R3 6 Pallets 0.75" 1920 64 R4.5 6 Pallets 1" 1536 48 R6 6 Pallets 1.5" 1024 32 R9 6 Pallets 2" 768 24 R12.1 6 Pallets 2.5" 608 19 R15.3 6 Pallets 3" 512 16 R18.5 6 Pallets 3.5" 416 13 R21.7 6 Pallets 4" 384 12 R25 6 Pallets 4.5" 320 10 R30 6 Pallets COMPLIANCES 1. ASTM C1289 Type II, Class 2 2. International Building Code (IBC) Section 2603, Foam Plastic 3. ASHRAE 90.1 4. CA Insulation Directory 5. Tested per NFPA 286 (ICC-ES AC12 Appendix B) 6. 1, 2, 3 or 4 hour Fire Rated Assemblies as shown in the UL Fire Resistance Directory TYPICAL PHYSICAL PROPERTIES Property Test Method Results Density, Overall, Nominal ASTM D1622 2.0 pcf Compressive Strength ASTM D1621 20 psi Flame Spread, Core2 ASTM E84 75 or less Smoke Developed, Core2 ASTM E84 <450 Air Barrier ASTM E2178 < 0.02 L/(s.m2 ) Water Vapor Transmission ASTM E96 < 1.5 perm Water Absorption ASTM C209 < 1% Vol. Dimensional Stability, Length and Width ASTM D2126 < 2% Linear Change Mold Resistance ASTM D3273 10, no defacement Service Temperatures 250°F max CONSTRUCTION APPLICATIONS 1. Stud walls 2. Cavity walls 3. Masonry walls 4. Exterior stucco 5. Re-siding 6. Vaulted-ceilings 7. Attics and crawls spaces 8. Limited roofing
Checkout happens on the official store. This page mirrors catalog facts in plain HTML for direct reading and crawlability.