SolaX X3-Ultra 30.0kW HV 3‑Phase Hybrid Inverter Key benefits 30kW three‑phase C&I hybrid inverter for larger commercial and industrial systems combining PV generation and high‑voltage lithium batteries. Supports up to 200% PV oversizing, 110% AC output and 200% EPS overload for 10 seconds, helping manage demanding site loads and short peaks. IP66‑rated, with Type II surge protection on AC and DC sides plus optional AFCI, suited to exposed plant rooms, rooftops and service yards. Brief description The SolaX X3‑Ultra 30.0kW HV 3‑Phase Hybrid Inverter is designed for three‑phase commercial and industrial projects that need a single platform for PV, battery storage and backup power. It offers smart management features including UPS‑level switchover, built‑in shadow tracking and smart load control, making it a practical choice for logistics hubs, small factories, retail sites and mixed‑use buildings. With support for up to 10 units in parallel and microgrid/generator functions, it can scale with project needs and integrate into wider energy strategies. Key features Three‑phase C&I hybrid inverter with 30kW rated output and EPS backup operation when paired with batteries. Max. 10 inverters in parallel for both on‑grid and off‑grid operation, plus microgrid and generator support for versatile system design. Max. 36A PV input per MPPT across three trackers, optimised for high‑power solar panels and flexible string layouts. Single‑unit UPS‑level switchover time below 10ms, with loads response time within 0.3s for smart loads such as heat pumps and EV chargers. VPP‑ready with compatibility options including OpenADR, IEEE2030.5, FCAS and API (feature to be upgraded in future firmware). Technical specifications PV input Max. recommended PV array power 60 kWp (X3‑ULT‑30K) Max. PV input voltage 1000 V (①) Rated PV input voltage 600 V Operation voltage range 120 ~ 950 V MPPT voltage range 160 ~ 950 V (②) Start-up voltage 200 V No. of MPP trackers / strings per MPP tracker 3 / (2 / 2 / 2) (X3‑ULT‑30K) Max. input current per MPPT 36 A / 36 A / 36 A (X3‑ULT‑30K) Max. input short circuit current per MPPT 45 A / 45 A / 45 A (X3‑ULT‑30K) AC input & output (on‑grid) Rated output power 30000 W (AS4777 29999 W, VDE4105 29900 W) (X3‑ULT‑30K) Rated output current 43.5 A (X3‑ULT‑30K) Max. output apparent power 30000 VA (AS4777 29999 VA, VDE4105 29900 VA) (X3‑ULT‑30K) Max. output continuous current 43.5 A (X3‑ULT‑30K) Rated AC voltage 3 / N / PE, 220 / 380 V; 3 / N / PE, 230 / 400 V Max. AC input apparent power 30000 VA (X3‑ULT‑30K) Max. AC input current 43.5 A (X3‑ULT‑30K) Rated AC frequency 50 Hz / 60 Hz Adjustable power factor range ~ 1 (0.8 lagging to 0.8 leading) THDi (rated power) < 3% Battery Battery type Lithium Battery voltage range 120 ~ 800 V (③④) Max. charge / discharge current 60 A (30 A × 2) EPS (off‑grid) output (with battery) Rated EPS output voltage, frequency 230 V / 400 V, 50 Hz / 60 Hz Rated EPS output power 30000 VA (30K) Peak EPS output power 2 times of rated power, 10 s Switchover time < 10 ms Efficiency Max. efficiency 98.0% European efficiency 97.7% Environment limit Ingress protection IP66 Operation temperature range -35 ~ 60°C (> 45°C derating) Max. operation altitude 3000 m Relative humidity 0 ~ 100% RH (condensing) Overvoltage category Mains: III, Battery: II, PV: II General Dimensions (W × H × D) 696 × 526 × 240 mm Net weight 47 kg Cooling concept Smart air cooling Communication interfaces Meter (RS‑485), DI × 2, DO × 1, Modbus Power consumption (night) < 5 W Topology Non‑isolated Certifications VDE4105, G99, AS4777, EN50549, CEI 0‑21, IEC61727, PEA/MEA, NRS‑097‑2‑1, RD1699, TOR Protection Protections Over / under voltage protection, DC reverse‑polarity protection, Residual current detection, Over temperature protection, DC isolation protection, Grid monitoring, DC injection monitoring, Back feed current monitoring Active anti‑islanding method Frequency shift Surge protection DC: Type II, AC: Type II Arc-fault circuit interrupter (AFCI) Optional Manufacturer notes Note ① The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter Note ② Input voltage exceeding the MPPT voltage range may triggers inverter protection Note ③ Compatible with a minimum of 3 units of HS Series batteries, but if the total voltage of the 3 batteries is less than 127V and there is no PV input, the system will not able to startup Note ④ When the voltage is below 180V, the inverter will limit the battery current to less than 20A Shipping Shipping is available to the UK, Ireland, Africa, the Caribbean and worldwide. If the shipping rate is not shown at checkout, please contact us on +44 2080640335 or [email protected] for a tailored shipping quote. UK expert support UK expert support is available to help with system design, product selection and technical questions for the SolaX X3‑Ultra 30.0kW HV 3‑Phase Hybrid Inverter. For commercial and industrial projects we recommend installation and commissioning through our trusted partners, ensuring compliance with local grid codes and safe integration of PV, batteries, backup loads and generators. You can contact us via phone, email or live chat, or visit our office for an in‑person consultation on your project requirements and hybrid system configuration. Documents available for download SolaX X3‑Ultra datasheet (includes X3‑ULT‑30)
Checkout happens on the official store. This page mirrors catalog facts in plain HTML for direct reading and crawlability.